Know who made it. See the evidence. Buy through one marketplace.
Handheld 8-Channel Cryotube Capper/Decapper from NEST Scientific for research and laboratory use.
NEST Cat. No.: 106008
Selling unit: Each
NEST Handheld 8-Channel Cryotube Capper/Decapper for Internal Thread Cryogenic Tubes (Cat. No. 106008)
| Specification | Listed detail |
|---|---|
| Detail | 8-channel operation for simultaneous capping and uncapping of up to eight cryogenic tubes |
| Detail | Designed for 0.5 mL and 1.0 mL NEST internal thread cryogenic tubes |
| Detail | Compatible with 8 × 12 freezer box configurations |
| Detail | Controlled mechanical operation provides consistent and repeatable tube closure |
| Detail | Stable torque control helps standardize the capping process |
| Detail | Helps reduce repetitive hand movements and operator fatigue |
| Detail | Supports faster processing of cryogenic sample batches |
| Detail | Handheld design provides flexibility for routine laboratory and biobank workflows |
| Detail | Dedicated base provides convenient support and storage for the handheld unit |
| Detail | Device surfaces can be wiped with alcohol for disinfection |
| Detail | Designed for sample storage and recovery workflows |
| Specification | Listed detail |
|---|---|
| Detail | Channel Configuration: 8-channel |
| Detail | Compatible Tube Volumes: 0.5 mL and 1.0 mL |
| Detail | Compatible Cap Type: Internal thread cap |
| Detail | Compatible Freezer Box Format: 8 × 12 |
| Detail | Compatible NEST Part Numbers: 612531, 612731 |
| Detail | Power Input: 100–240 V AC, 50/60 Hz, Power Output: 10.0 V DC, 1.0 A, constant voltage |
| Detail | Dimensions |
| Detail | Overall dimensions: 210 × 120 × 295 mm (L × W × H) |
| Detail | Base: 210 × 120 × 130 mm |
| Detail | Handheld capper: 100 × 40 × 260 mm |
| Detail | Weight |
| Detail | Total weight: 796 g |
| Detail | Base: 407 g |
| Detail | Handheld capper: 389 g |
The NEST Handheld 8-Channel Cryotube Capper/Decapper is designed to improve the speed, consistency, and ergonomics of cryogenic sample handling in biobanking, research, and laboratory workflows. The handheld device enables simultaneous capping or uncapping of up to eight compatible cryogenic tubes, helping laboratories process samples more efficiently than individually opening or closing tubes by hand. Designed specifically for NEST 0.5 mL and 1.0 mL internal thread cryogenic tubes arranged in an 8 × 12 freezer box format, the system provides controlled, repeatable mechanical capping and uncapping. Stable torque control helps provide consistent closure while reducing the repetitive hand movements associated with manual tube processing.
The combination of a handheld capper and dedicated base provides flexibility for medium- to high-throughput sample management applications. The device is particularly well suited for biobanks, sample repositories, clinical research laboratories, pharmaceutical research, and other facilities where large numbers of cryogenic samples must be stored, retrieved, and processed. By allowing an entire row of eight tubes to be handled at the same time, the system can help reduce processing time, minimize operator hand fatigue, and reduce unnecessary handling of individual cryogenic tubes.
The NEST 8-Channel Cryotube Capper/Decapper is designed to simultaneously cap or uncap up to eight compatible cryogenic tubes. It helps improve efficiency and consistency when processing cryogenic samples in biobanking, sample storage, and laboratory workflows.
The 106008 capper/decapper is designed for NEST 0.5 mL and 1.0 mL internal thread cryogenic tubes, including Cat. Nos. 612531 and 612731.
No. Cat. No. 106008 is designed for compatible internal thread cryogenic tubes. For compatible 2.0 mL and 4.0 mL external thread tubes, NEST offers the 106009 6-channel cryotube capper/decapper.
The device has an 8-channel configuration, allowing up to eight compatible cryogenic tubes to be capped or uncapped simultaneously.
The 106008 is designed for compatible tubes arranged in an 8 × 12 freezer box configuration.
Processing eight tubes simultaneously can reduce the time required for repetitive sample handling. The mechanical capping process also helps provide more consistent closure while reducing repetitive hand movements and operator fatigue compared with manually opening and closing individual tubes.
Yes. According to the NEST product data sheet, the device provides stable torque control to support standardized and reproducible mechanical capping.
No. The 106008 is a handheld, assisted capping and uncapping device. It is intended to increase throughput while retaining the flexibility and control of manual sample-processing workflows.
The device is suitable for biobanks, sample repositories, pharmaceutical and biotechnology laboratories, clinical research facilities, and other laboratories that routinely store, retrieve, or process multiple cryogenic samples.
The device accepts a 100–240 V AC, 50/60 Hz power input. The specified power output is 10.0 V DC, 1.0 A constant voltage.
The complete device weighs approximately 796 g. The handheld capper weighs approximately 389 g, and the base weighs approximately 407 g.
The overall dimensions are approximately 210 × 120 × 295 mm (L × W × H). The handheld capper measures approximately 100 × 40 × 260 mm, and the base measures approximately 210 × 120 × 130 mm.
The NEST data sheet specifies wiping with alcohol as the disinfection method. Users should follow applicable laboratory procedures and product instructions when cleaning the device.
Yes. The specifications identify both a handheld capper and base as components of the device.
The 106008 is an 8-channel device designed for compatible 0.5 mL and 1.0 mL internal thread tubes in an 8 × 12 configuration. The 106009 is a 6-channel device designed for compatible 2.0 mL and 4.0 mL external thread tubes in a 6 × 8 configuration.
This product is manufactured by NEST® and sold through ABMIUM without relabelling.
ABMIUM supports global orders. Availability, shipping requirements and applicable import arrangements are confirmed before fulfilment where required.
Yes. Send your target, sample, application and experimental conditions through ABMIUM MATCH or technical support.
Unless the listing expressly states otherwise, ABMIUM products are supplied for research use only and are not for diagnostic or therapeutic use.