Manufactured by:Bioer
Save 15%ABMIUM Verified™RUO

HIV RT-PCR Fluorescence Quantitative Detection Kit

HIV RT-PCR Fluorescence Quantitative Detection Kit from Bioer

SKU:
ABM46985
Manufacturer SKU
BSB24S1C
Product type
RT-PCR Kit
TargetHIV
ApplicationsRT-PCR
Species / reactivityHuman, Virus
Sample typeSerum, Plasma, Viral sample, PCR products, Nucleic acid extract

Manufacturer provenance

Manufactured by:
Bioer
Sold by:
ABMIUM
Fulfilled from:
Manufacturer facility or confirmed fulfilment location

Know who made it. See the evidence. Buy through one marketplace.

Product description

HIV RT-PCR Fluorescence Quantitative Detection Kit from Bioer is a nucleic acid detection reagent for research use.

For research use only.

Pack sizes and catalogue numbers

ABMIUM SKU Pack size Bioer catalogue number
ABM46985 32T BSB24S1C
ABM46986 48T BSB24M1C

Technical specifications

Target HIV
Research Area Blood-Borne Disease, Human Disease, Molecular Biology
Reactivity Human, Virus
Tested Applications RT-PCR
Form Kit
Storage and period of validity The kit need to be transported under freezing conditions. The kit should be stored at -25°C--15°C away from light, and avoid repeated freeze-thaw more than 5 times. The kit can be stored for up to 12 months if all components are kept in the manner above. (Please use the kit in the period of validity). Specimen Collection, Storage And Transportation Specimen type: serum or plasma. Specimen Collection: 2.1 Serum: Draw 2mL venous blood of subject with a sterile syringe and injected into a sterile collection tube, which was placed at room temperature for no more than 4 hours until serum was precipitated, or centrifuge at ro
Shelf Life Up to 12 months.
Detection Method Fluorescence
Assay Data Quantitative
Sample Type Serum, Plasma, Viral sample, PCR products, Nucleic acid extract
Material Required But Not Provided QuantGene 9600 Fluorescent Quantitative Detection System, LineGene 9600 Plus Fluorescent Quantitative Detection System, Real Time PCR System, real-time PCR instrument
Components Ingredients BSB24S1C BSB24M1C size 32 Tests/kit 48 Tests/kit Amplification reagent 2×RT-PCR Buffer Enzyme mix HIV-1 Primer /Probe Control Internal control Positive control Negative control Standard control Standard.

Product documentation

Download Bioer product manual. Covers 32T (BSB24S1C), 48T (BSB24M1C).

Bioer manufacturer product information

Image shows representative Bioer reagent packaging. Supplied packaging and contents depend on the selected catalogue number.

Key facts & specifications
Research areas
Blood-Borne Disease, Human Disease, Molecular Biology
Assay type
RT-PCR
Detection method
Fluorescence
Form / buffer
Kit
Quantity per pack
32T; 48T
Validation & performance evidence
ABMIUM Validated™ ABMIUM Verified™ Expected performance Not suitable

Sample type validation

Sample compatibility evidence using the same validation key.

Sample typeSerumPlasmaViral samplePCR productsNucleic acid extract
Sample compatibility
Identifiers & database references
Manufacturer SKU
BSB24S1C
Storage, stability & shipping
Shelf life
Up to 12 months.
Storage conditions
and period of validity The kit need to be transported under freezing conditions. The kit should be stored at -25°C--15°C away from light, and avoid repeated freeze-thaw more than 5 times. The kit can be stored for up to 12 months if all components are kept in the manner above. (Please use the kit in the period of validity). Specimen Collection, Storage And Transportation Specimen type: serum or plasma. Specimen Collection: 2.1 Serum: Draw 2mL venous blood of subject with a sterile syringe and injected into a sterile collection tube, which was placed at room temperature for no more than 4 hours until serum was precipitated, or centrifuge at ro
Long-term storage
and period of validity The kit need to be transported under freezing conditions. The kit should be stored at -25°C--15°C away from light, and avoid repeated freeze-thaw more than 5 times. The kit can be stored for up to 12 months if all components are kept in the manner above. (Please use the kit in the period of validity). Specimen Collection, Storage And Transportation Specimen type: serum or plasma. Specimen Collection: 2.1 Serum: Draw 2mL venous blood of subject with a sterile syringe and injected into a sterile collection tube, which was placed at room temperature for no more than 4 hours until serum was precipitated, or centrifuge at ro
Storage warning
Store according to the component-specific conditions stated in the product manual.
Compliance & documents
CE marked
No
ISO certifications
ISO 9001, ISO 13485, ISO 14001
Product manual
Open manual
Frequently asked questions
Who manufactured this product?

This product is manufactured by Bioer and sold through ABMIUM without relabelling.

Can ABMIUM ship this product internationally?

ABMIUM supports global orders. Availability, shipping requirements and applicable import arrangements are confirmed before fulfilment where required.

Can I check suitability before ordering?

Yes. Send your target, sample, application and experimental conditions through ABMIUM MATCH or technical support.

Is this product for clinical use?

Unless the listing expressly states otherwise, ABMIUM products are supplied for research use only and are not for diagnostic or therapeutic use.

Bioer
£345.00£293.25