Manufactured by:BT LAB
Save 15%RUO

Human Cryptochrome-1, CRY1 ELISA Kit

Human Cryptochrome-1, CRY1 ELISA Kit

SKU:
ABM216154
Manufacturer SKU
E5126Hu
Product type
ELISA Kits
TargetCRY1
ApplicationsELISA
Species / reactivityHuman
Sample typeSerum, Plasma, Cell culture supernatants, Ascites, Tissue homogenates

Manufacturer provenance

Manufactured by:
BT LAB
Sold by:
ABMIUM
Fulfilled from:
Manufacturer facility or confirmed fulfilment location

Know who made it. See the evidence. Buy through one marketplace.

Product description

Background

Transcriptional repressor which forms a core component of the circadian clock. The circadian clock, an internal time-keeping system, regulates various physiological processes through the generation of approximately 24 hour circadian rhythms in gene expression, which are translated into rhythms in metabolism and behavior. It is derived from the Latin roots 'circa' (about) and 'diem' (day) and acts as an important regulator of a wide array of physiological functions including metabolism, sleep, body temperature, blood pressure, endocrine, immune, cardiovascular, and renal function. Consists of two major components: the central clock, residing in the suprachiasmatic nucleus (SCN) of the brain, and the peripheral clocks that are present in nearly every tissue and organ system. Both the central and peripheral clocks can be reset by environmental cues, also known as Zeitgebers (German for 'timegivers'). The predominant Zeitgeber for the central clock is light, which is sensed by retina and signals directly to the SCN. The central clock entrains the peripheral clocks through neuronal and hormonal signals, body temperature and feeding-related cues, aligning all clocks with the external light/dark cycle. Circadian rhythms allow an organism to achieve temporal homeostasis with its environment at the molecular level by regulating gene expression to create a peak of protein expression once every 24 hours to control when a particular physiological process is most active with respect to the solar day. Transcription and translation of core clock components (CLOCK, NPAS2, ARNTL/BMAL1, ARNTL2/BMAL2, PER1, PER2, PER3, CRY1 and CRY2) plays a critical role in rhythm generation, whereas delays imposed by post-translational modifications (PTMs) are important for determining the period (tau) of the rhythms (tau refers to the period of a rhythm and is the length, in time, of one complete cycle). A diurnal rhythm is synchronized with the day/night cycle, while the ultradian and infradian rhythms have a period shorter and longer than 24 hours, respectively. Disruptions in the circadian rhythms contribute to the pathology of cardiovascular diseases, cancer, metabolic syndromes and aging. A transcription/translation feedback loop (TTFL) forms the core of the molecular circadian clock mechanism. Transcription factors, CLOCK or NPAS2 and ARNTL/BMAL1 or ARNTL2/BMAL2, form the positive limb of the feedback loop, act in the form of a heterodimer and activate the transcription of core clock genes and clock-controlled genes (involved in key metabolic processes), harboring E-box elements (5'-CACGTG-3') within their promoters. The core clock genes: PER1/2/3 and CRY1/2 which are transcriptional repressors form the negative limb of the feedback loop and interact with the CLOCK|NPAS2-ARNTL/BMAL1|ARNTL2/BMAL2 heterodimer inhibiting its activity and thereby negatively regulating their own expression. This heterodimer also activates nuclear receptors NR1D1/2 and RORA/B/G, which form a second feedback loop and which activate and repress ARNTL/BMAL1 transcription, respectively. CRY1 and CRY2 have redundant functions but also differential and selective contributions at least in defining the pace of the SCN circadian clock and its circadian transcriptional outputs. More potent transcriptional repressor in cerebellum and liver than CRY2, though more effective in lengthening the period of the SCN oscillator. On its side, CRY2 seems to play a critical role in tuning SCN circadian period by opposing the action of CRY1. With CRY2, is dispensable for circadian rhythm generation but necessary for the development of intercellular networks for rhythm synchrony. Capable of translocating circadian clock core proteins such as PER proteins to the nucleus. Interacts with CLOCK-ARNTL/BMAL1 independently of PER proteins and is found at CLOCK-ARNTL/BMAL1-bound sites, suggesting that CRY may act as a molecular gatekeeper to maintain CLOCK-ARNTL/BMAL1 in a poised and repressed state until the proper time for transcriptional activation. Represses the CLOCK-ARNTL/BMAL1 induced transcription of BHLHE40/DEC1. Represses the CLOCK-ARNTL/BMAL1 induced transcription of ATF4, MTA1, KLF10 and NAMPT (By similarity). May repress circadian target genes expression in collaboration with HDAC1 and HDAC2 through histone deacetylation. Mediates the clock-control activation of ATR and modulates ATR-mediated DNA damage checkpoint. In liver, mediates circadian regulation of cAMP signaling and gluconeogenesis by binding to membrane-coupled G proteins and blocking glucagon-mediated increases in intracellular cAMP concentrations and CREB1 phosphorylation. Inhibits hepatic gluconeogenesis by decreasing nuclear FOXO1 levels that downregulates gluconeogenic gene expression (By similarity). Besides its role in the maintenance of the circadian clock, is also involved in the regulation of other processes. Represses glucocorticoid receptor NR3C1/GR-induced transcriptional activity by binding to glucocorticoid response elements (GREs). Plays a key role in glucose and lipid metabolism modulation, in part, through the transcriptional regulation of genes involved in these pathways, such as LEP or ACSL4 (By similarity). Represses PPARD and its target genes in the skeletal muscle and limits exercise capacity (By similarity). Plays an essential role in the generation of circadian rhythms in the retina (By similarity). Represses the transcriptional activity of NR1I2 (By similarity).

Test principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Human CRY1 antibody. CRY1 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Human CRY1 Antibody is added and binds to CRY1 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated CRY1 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Human CRY1. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.
Key facts & specifications
Research areas
Neuroscience
Also known as
CRY 1;CRY1;Cryptochrome-1
Assay type
Sandwich
Detection method
Colorimetric (450 nm)
Sensitivity
7.31ng/L
Detection range
15-3000ng/L
Plate format
Pre-coated ELISA plate
Assay duration
1h 30m
Molecular weight
66,395 Da
Quantity per pack
48T, 96T
Validation & performance evidence
ABMIUM Validated™ ABMIUM Verified™ Expected performance Not suitable

Application validation matrix

Evidence status by application and model.

EvidenceSerumPlasmaCell culture supernatantsAscitesTissue homogenates
Compatibility
Identifiers & database references
Manufacturer SKU
E5126Hu
Gene symbol
CRY1
Gene ID
1407
UniProt accession
Q16526
Storage, stability & shipping
Shelf life
Store at -20°C for one year. Or store at 2-8°C for 6 months. If individual reagents are opened it is recommended that the kit be used within 1 month. Avoid repeated thaw cycles. *This product is for research use only, not for use in diagnosis procedures. It’s highly recommended to read this instruction entirely before use.
Storage conditions
2-8ºC
Compliance & documents
Datasheet
Open datasheet
Product manual
Open manual
Frequently asked questions
Who manufactured this product?

This product is manufactured by BT LAB and sold through ABMIUM without relabelling.

Can ABMIUM ship this product internationally?

ABMIUM supports global orders. Availability, shipping requirements and applicable import arrangements are confirmed before fulfilment where required.

Can I check suitability before ordering?

Yes. Send your target, sample, application and experimental conditions through ABMIUM MATCH or technical support.

Is this product for clinical use?

Unless the listing expressly states otherwise, ABMIUM products are supplied for research use only and are not for diagnostic or therapeutic use.

BT LAB
£240.93£205.00