{"product_id":"nest-nest-luer-connector-3-32-male-luer-connector-pp-material-non-sterile-double-bag-package-100-pcs-pack-746621","title":"NEST® NEST Luer Connector, 1\/16″ Male Luer Connector, PP Material, Non-Sterile, Double Bag Package, 100 pcs\/pack","description":"\u003cp\u003eNEST Luer Connector, 1\/16″ Male Luer Connector, PP Material, Non-Sterile, Double Bag Package, 100 pcs\/pack from NEST Scientific for research and laboratory use.\u003c\/p\u003e\u003ch3\u003eNEST Luer Connector, 1\/16″ Male Luer Connector, PP Material, Non-Sterile, Double Bag Package, 100 pcs\/pack\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eNEST Cat. No.:\u003c\/strong\u003e 746621\u003cbr\u003e\u003cstrong\u003eSelling unit:\u003c\/strong\u003e Pack of 100\u003c\/p\u003e\u003cp\u003eNEST Luer Connector, 1\/16″ Male Luer Connector, PP Material, Non-Sterile, Double Bagged (Cat. No. 746621)\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eListed detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Designed to connect with compatible female Luer fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Hose-barb design supports a secure connection to compatible tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Simple twist connection enables fast fluid-path assembly and disconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• For tubing 1\/16\" Inner Diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e• Double-bagged and packaged 100 pieces per bag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Non-sterile for use as an assembly component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch4\u003eProduct Details\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eListed detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Manufactured from USP Class VI polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Hose-barb configuration helps retain compatible tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Male Luer interface connects to compatible female Luer connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Compatible Luer caps are available to close the connector when disconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e• Supports either electron beam irradiation at 50–55 kGy or steam sterilization at 121°C for 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e• No leakage at room temperature under 410 kPa for 30 minutes under the documented test conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch4\u003eQuality Details\u003c\/h4\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eListed detail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• USP Class VI compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for sealing performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for radiation resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for freeze resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for acid and alkali resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for bacterial endotoxins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for nucleases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Tested for insoluble particulates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e• Evaluated for high-temperature and high-pressure resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-4 hemolysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-5 and USP \u0026lt;87\u0026gt; in vitro cytotoxicity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-6 intramuscular implantation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-23 skin irritation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-11 and USP \u0026lt;88\u0026gt; systemic toxicity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Biocompatibility testing includes ISO 10993-10 irritation and delayed hypersensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetail\u003c\/th\u003e\n\u003ctd\u003e• Extractables and leachables testing performed with reference to USP General Chapters \u0026lt;665\u0026gt; and \u0026lt;1665\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNEST Male Luer Connectors provide a compact and practical solution for joining tubing to compatible female Luer components. The hose-barb design supports proper tubing attachment, while the twist-to-connect interface helps simplify fluid-path assembly, equipment connection and component changes. Multiple hose barb sizes accommodate tubing with inner diameters from 1\/16 inch through 1\/4 inch. Polypropylene construction, USP Class VI compliance and documented performance testing support use in media and buffer transfer, filtration, sampling and other biopharmaceutical fluid-handling workflows.\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked Questions\u003c\/h5\u003e\n\u003ch5\u003eWhat are NEST Luer Connectors used for?\u003c\/h5\u003e\n\u003cp\u003eNEST Luer Connectors create compact fluid-transfer connections between compatible components in single-use bioprocessing systems. They can connect tubing assemblies, bags, bottles, filters, sampling containers and compatible processing equipment.\u003c\/p\u003e\n\u003ch5\u003eWhat is the difference between male and female Luer connectors?\u003c\/h5\u003e\n\u003cp\u003eA male Luer connector has an external mating interface that connects to a compatible female Luer fitting. A female Luer connector has an internal mating interface that connects to a compatible male Luer fitting. Both versions include a hose barb for attachment to appropriately sized tubing.\u003c\/p\u003e\n\u003ch5\u003eWhich tubing sizes are available?\u003c\/h5\u003e\n\u003cp\u003eMale and female NEST Luer Connectors are available for tubing with the following inner diameters: • 1\/16″ (1.6 mm) • 3\/32″ (1.9 mm) • 1\/8″ (3.2 mm) • 5\/32″ (4.0 mm) • 3\/16″ (4.8 mm) • 1\/4″ (6.4 mm)\u003c\/p\u003e\n\u003ch5\u003eHow do I choose the correct connector size?\u003c\/h5\u003e\n\u003cp\u003eSelect the male or female interface required by the mating component and match the hose-barb size to the tubing’s inner diameter. Confirm dimensional, material and functional compatibility with the complete fluid-transfer assembly before ordering.\u003c\/p\u003e\n\u003ch5\u003eHow are male and female Luer connectors joined?\u003c\/h5\u003e\n\u003cp\u003eAlign the compatible male and female Luer interfaces and twist the two components together until securely connected. Avoid overtightening or using excessive force.\u003c\/p\u003e\n\u003ch5\u003eHow are the connectors disconnected?\u003c\/h5\u003e\n\u003cp\u003eHold both connector components and twist them apart. After separation, install the appropriate Luer cap or plug to close and protect each open fluid path.\u003c\/p\u003e\n\u003ch5\u003eWhich closure is used with each connector?\u003c\/h5\u003e\n\u003cp\u003eA compatible Luer cap closes a male Luer connector. A compatible Luer plug closes a female Luer connector. Verify the closure type and interface before ordering.\u003c\/p\u003e\n\u003ch5\u003eWhy do the connectors have hose barbs?\u003c\/h5\u003e\n\u003cp\u003eThe hose-barb design helps retain compatible tubing and supports proper assembly of the fluid-transfer line. Tubing material, inner diameter, wall thickness and assembly method should be evaluated for the intended application.\u003c\/p\u003e\n\u003ch5\u003eCan the connectors rotate after tubing is attached?\u003c\/h5\u003e\n\u003cp\u003eThe connector design allows the joined components to rotate during connection, helping reduce tubing twisting and supporting more flexible assembly positioning.\u003c\/p\u003e\n\u003ch5\u003eWhat materials are used to manufacture the connectors?\u003c\/h5\u003e\n\u003ch5\u003eAre the Luer connectors supplied sterile?\u003c\/h5\u003e\n\u003cp\u003eNo. The connectors are supplied non-sterile and double-bagged for use as components in fluid-transfer assemblies.\u003c\/p\u003e\n\u003ch5\u003eCan the connectors be sterilized?\u003c\/h5\u003e\n\u003cp\u003eThe connectors support either electron beam irradiation at 50–55 kGy or steam sterilization at 121°C for 30 minutes. The selected method and completed assembly should be appropriately validated before use.\u003c\/p\u003e\n\u003ch5\u003eCan electron beam irradiation and steam sterilization both be used?\u003c\/h5\u003e\n\u003cp\u003eNo. The two sterilization methods are mutually exclusive. Do not apply both methods to the same connector or completed assembly.\u003c\/p\u003e\n\u003ch5\u003eWhat pressure have the connectors been tested to withstand?\u003c\/h5\u003e\n\u003cp\u003eThe connectors demonstrated no leakage at room temperature under 410 kPa for 30 minutes under the documented test conditions. Users should evaluate the connectors with their specific tubing, mating components, process fluids and operating conditions.\u003c\/p\u003e\n\u003ch5\u003eWhat performance testing is referenced?\u003c\/h5\u003e\n\u003cp\u003eThe product documentation references sealing, freeze resistance, radiation resistance, acid and alkali resistance, bacterial endotoxin, nuclease, insoluble particulate, and high-temperature and high-pressure testing.\u003c\/p\u003e\n\u003ch5\u003eWhat biocompatibility testing is referenced?\u003c\/h5\u003e\n\u003cp\u003eThe documented testing includes ISO 10993-4 hemolysis, ISO 10993-5 and USP \u0026lt;87\u0026gt; in vitro cytotoxicity, ISO 10993-6 implantation, ISO 10993-23 skin irritation, ISO 10993-11 and USP \u0026lt;88\u0026gt; systemic toxicity, and ISO 10993-10 irritation and delayed hypersensitivity. For additional information, review the official ISO 10993-1 biological-evaluation standard, USP \u0026lt;87\u0026gt; Biological Reactivity Tests, In Vitro and USP \u0026lt;88\u0026gt; Biological Reactivity Tests, In Vivo.\u003c\/p\u003e\n\u003ch5\u003eHas extractables and leachables testing been performed?\u003c\/h5\u003e\n\u003cp\u003eThe product documentation references extractables and leachables testing based on USP General Chapters \u0026lt;665\u0026gt; and \u0026lt;1665\u0026gt;. Review the official USP \u0026lt;1665\u0026gt; guidance and read NEST’s overview of extractables and leachables in bioprocessing applications.\u003c\/p\u003e\n\u003ch5\u003eHow are the Luer connectors packaged?\u003c\/h5\u003e\n\u003cp\u003eMale and female Luer Connectors are double-bagged and packaged 100 pieces per bag.\u003c\/p\u003e\n\u003ch5\u003eAre NEST Luer Connectors compatible with other brands?\u003c\/h5\u003e\n\u003cp\u003eThe connectors are designed to connect with compatible Luer fittings without modification. Users should confirm dimensional, material and functional compatibility with the intended mating component before incorporating a connector into a validated process.\u003c\/p\u003e\n\u003ch5\u003eWhat related products are available?\u003c\/h5\u003e","brand":"NEST®","offers":[{"title":"1\/16″ Male Luer Connector · PP Material · Non-Sterile · Double Bag Package \/ Pack of 100","offer_id":57311556534612,"sku":"ABM112483","price":77.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1040\/1782\/2036\/files\/746621.jpg?v=1790545557","url":"https:\/\/www.abmium.com\/products\/nest-nest-luer-connector-3-32-male-luer-connector-pp-material-non-sterile-double-bag-package-100-pcs-pack-746621","provider":"ABMIUM","version":"1.0","type":"link"}